Cummins Onan

Compare Propane Commercial Mobile Generators

Select Unit Of Measurement
Click on image for larger view.
Additional options and variances may apply.
View spec sheet for more details.
Commercial QG 4000
KY
Spec: L
Documents
Spec Sheet
a-1399
a-1399 (337 KB)
Operators Manual
981-0159D
981-0159D (956 KB)
Fire Rescue Applications
Rescue
Pumper
Aerial
Brush Truck
ARFF
Command Center
HazMat
Ambulance
Utility/Telecom Applications
Service Vehicle
Aerial
Van
Other
Speciality Applications
Mobile Service
Communication
Trailer
Food Service
Medical
Generator Ratings
Hertz 60
Fuel Gasoline
Watts 4000
kW 4.0
RPM 3600
AC Voltage Available 120
AC Amps 33.3
Single Phase
Circuit Breaker 1 pole 30A
AC Voltage 120
Voltages-Single Phase Amperes
120 - 33.3
Dimensions
Weight-Dry (Pounds)
174.0
Length (Inches)
30.5
Width (Inches)
20.6
Height (Inches)
16.4
Average Fuel Consumption
No Load (Gal/h)
0.29
Half Load - 50% (Gal/h)
0.48
Full Load (Gal/h)
0.71
Engine Detail
Number of Cylinders/Type 1/OHV
Cooling System Type Air
Oil Capacity (Quarts)
1.6
Comments
  Additional configurations available, see spec sheet. Includes adjustable 220-240, Reconnectable to 110/220, 115/230 or 120/240.