Cummins Onan

Cummins Onan Portable Generators

Select Unit Of Measurement
Click on image for larger view.
Additional options and variances may apply.
View spec sheet for more details.
RV QD 12500
HDKCB
Spec: D
Documents
Specification Sheet
a-1483
a-1483 (331 KB)
Service Diagram
spd_hdkc
spd_hdkc (11 KB)
Operator Manual
981-0173
981-0173 (2.65 MB)
Typical Generator Applications
Motorized (Type A & C)
  2 Air Conditioners, Diesel
  3 Air Conditioners, Diesel
Generator Ratings
Hertz 60
Fuel Diesel
Watts 12500
RPM Constant Speed
AC Voltage Available 120/240
AC Amps 104.0/52.0
Single Phase
Circuit Breaker 50A 2-pole
AC Voltage 120
Voltages-Single Phase Amperes
120/240 - 104.0/52.0
Dimensions
Weight-Dry (Pounds)
770.0
Length (Inches)
41.4
Width (Inches)
24.5
Height (Inches)
27.0
Average Fuel Consumption
No Load (Gal/h)
0.1
Half Load - 50% (Gal/h)
0.48
Full Load (Gal/h)
1.2
Performance @ 37.78° C, 152 M. Altitude
Air Conditioner Starting Three
With Additional Watts Available 4000
Engine Detail
Number of Cylinders/Type 3/In-line vertical
Cooling System Type Liquid
Maximum Power (hp) 27.0
Oil Capacity (Quarts)
5.9
Sound Level 10 Feet in dB(A) @ Half Load (typical RV installation) 68